刚看到有人发42PF7320Z/93的内部资料,刚好手上也有一份同机的内部资料。
Symptom
Power supply not working. ----故障:电源不工作
Cure
RESTRICTIONS:
This info is only valid for 42" and 50" models.-----只适合42"和50"
CAUSE: 原因电源变压器T8201失效(产品代码week0529 上标贴PH-V4T82010
The transformer from "Clover" (pos. T8201, production code < week 0529) can be defective. On the transformer the following is indicated: PH-V4T8201, followed by a date code. When this datecode starts with "SC", the quality of the part is questionable.
CURE:
Replace the PSU (board level repair). For the correct order codes, see the SDI PDP Repair Manual.
Note: After replacement, the new PSU board must be adjusted to the PDP. This is explained in the SDI PDP Repair Manual.
TIP:
For adminstrative reasons, this PDP panel is listed in the website's database under chassis name "PDP SDI".
You can use the "Product<>Chassis relation" link to find the CTNs belonging to this chassis.
TV05-0145_SDI_PDP_bad_transformer.PDF
(524.05 KB)
---------------------------------
thankyou very much, thanks your share
---------------------------------
Thank You very much.
---------------------------------
分享。症状
电源不工作。 ----故障:电源不工作
治疗
限 制;
这个信息是只适用于42“和50”模式.-----只适合42“和50”
原因:原因电源变压器T8201失效(产品代码week0529上标贴PH值,V4T82010
从变压器“四叶草”(pos.,生产代码T8201“周0529)可以被损坏。在变压器以下是表明:pH值V4T8201,由1日期代码。当这个生产日期开始的“资深”的零件质量有问题。
固化:
替换电源(板级维修)。对于正确的顺序码,看到SDI的等离子维修手册。
注意:在更换新电源板必须调整到PDP。这说明在SDI等离子维修手册。
提示:
对于行政上的原因,这PDP面板被列在网站的数据库在底盘名称“等离子空间数据基础设施”。
您可以使用“产品”“底盘的关系”链接找到箱数属于该底盘。
---------------------------------
多谢楼主大公无私的奉献!
---------------------------------
多谢楼主大公无私的奉献!